Pallet Rack Capacity Calculator

Turn pallet weight and beam span into the capacity you actually get per level — and the beam size that carries it with margin.

Short answerLoad per level = pallets per level × weight per pallet. A beam pair is rated for a uniformly distributed load (UDL) at a given length; capacity falls as the span grows, so always read the rating at your beam length and keep ~15% margin.

Want this on your own domain?

We build this calculator as an embeddable tool — engineered, SEO- and AI-ready, delivered in 5 business days for a flat $2,800.

Get yours in 5 days

How it's calculated

Selective rack capacity is set at two levels. Each beam pair carries the pallets on one level as a uniformly distributed load, and that rating drops as the beam gets longer. The upright frame then carries the sum of every level above it, limited by height, bracing and the down-aisle/​cross-aisle condition. Size the beam for the load per level with margin, then confirm the frame for the full column of levels.

Load per level = pallets/level × weight/pallet Beam UDL rating ∝ 1 ÷ span (read at your length) Design ≤ ~85% of rated UDL
Worked example
  1. Load per level = 2 × 1,000 = 2,000 kg.
  2. At 2.75 m span, a 4.0″ beam is borderline.
  3. Use a 4.5″ beam to keep ≥15% margin.

Reference tables

Typical selective step-beam UDL by size (pair, at ~2.75 m span)

BeamApprox. UDL (kg/pair)
3.5″1,500
4.0″2,000
4.5″2,400
5.0″3,000
6.0″4,000

How span changes a beam rating

SpanEffect on UDL
Shorter than ratedHigher capacity
At rated lengthNameplate UDL
Longer than ratedLower capacity — size up

A number the tables do not give: two 1,000 kg pallets on a 2.75 m level is 2,000 kg, which puts a 4.0″ beam at its limit — the 4.5″ is the safe pick.

See a live tool in action

This calculation is exactly what our storage-rack quote-simulator runs live. Open it to see how the same inputs become a full layout, beam selection and quote on your own domain:

Storage Rack quote-simulator▶ OPEN DEMO Packaging / box simulator▶ OPEN DEMO Conduit Fill · NEC▶ LIVE CALCULATOR

FAQ

Is beam capacity per beam or per pair?

Ratings are almost always for the pair of beams on one level, as a uniformly distributed load. Two point loads near the ends are more severe than a UDL — check with the maker if pallets are narrow.

Why does a longer beam carry less?

Bending moment grows with span for the same load, so a longer beam hits its stress limit at a lower load. Read the rating at your exact beam length, not a generic number.

What safety margin should I keep?

Keep design load at roughly 85% of the rated UDL — about a 15% cushion — to absorb uneven loading and impact.

Does the upright frame also limit capacity?

Yes. The frame carries every level above it and is limited by height and bracing. A strong beam on a tall, lightly braced frame can still be governed by the upright.

This page is a reference aid. Always verify against RMI/ANSI MH16.1 and the rack manufacturer’s load charts. Figures shown are for orientation, not a stamped design.